原始内容
name: iaiops-building description: >- Building edition of iaiops — facility / HVAC / BMS / 厂务 over BACnet/IP (ASHRAE 135): Who-Is discovery, object/point lists, presentValue snapshots, COV capture, TrendLog reads, one MOC-gated property write; plus Modbus-TCP/RTU for meters/chillers and optional plain MQTT for IoT sensors, with the cross-protocol brain. Use when the task mentions BACnet, BACnet-IP, HVAC, AHU, chiller, VAV, BMS, building automation, facility management, 厂务, 楼宇自控, Who-Is, presentValue, or TrendLog; also IO-Link masters for smart building sensors (JSON interface, read-only), and the vendor supervisory-controller REST layer above BACnet (Metasys/OpenBlue, Niagara/oBIX) for point/alarm/trend reads and one MOC-gated command. Read-first, MOC-gated writes.
iaiops-building — 楼宇/厂务 edition(BACnet + Modbus + IO-Link + MQTT + 脑)
启动:IAIOPS_MCP=building / iaiops-mcp-building(= bacnet + modbus + opcua + iolink + 脑)。
IoT 传感器走 MQTT 时叠加:IAIOPS_MCP=building,sparkplug。
安装:pip install iaiops[building]。BACnet 的 host 是本机 BACnet/IP 接口
(ip 或 ip/mask)。
工具
BACnet/IP(read-first;暖通/楼宇/厂务)
bacnet_discover— Who-Is:本地 BACnet/IP 网上的设备bacnet_object_list— 设备的 object/point 列表bacnet_read_property— 单对象属性(默认 presentValue)bacnet_read_points— 所有 analog/binary/multistate 点的 presentValue(HVAC 快照)bacnet_cov_subscribe— 单对象有界 Change-of-Value 捕获bacnet_read_trend_log— 读设备 TrendLog 缓冲记录bacnet_write_property— [WRITE][HIGH][MOC] 写单对象属性(默认 off:dry_run=True+ 审批双确认;可指挥楼宇设备 — 设定值、输出)
Modbus-TCP / Modbus-RTU(只读;电表/冷机/表计)
modbus_read_holdingmodbus_read_inputmodbus_read_coilsmodbus_read_discretemodbus_detect_byte_order/modbus_list_templates/modbus_apply_templatemodbus_health_summary
IO-Link(只读;主站 JSON 接口 — 楼宇智能传感器)
iolink_master_info— 主站身份(/deviceinfo)iolink_ports— 有界端口扫描(≤32:mode/status + 在线设备身份)iolink_device_info— 单端口设备身份iolink_read_pdin— 过程数据输入(raw hex + 字节数组;按 IODD 解码)iolink_read_isdu— ISDU 参数读(index/subindex 有界)iolink_scan— 主站 + 全端口一次性快照- 配置
flavor: iotcore(ifm IoT-Core,默认)或rest(plain-REST 主站);v1 只读
BAS 控制器层(edition 工具;厂商监控控制器 REST,在 BACnet 之上)
厂商监控控制器(Johnson Controls Metasys/OpenBlue、Tridium Niagara oBIX/REST)把大量 BACnet
现场点/告警/趋势聚合在一个带鉴权的企业 REST 接口后面——与 bacnet(现场总线)互补、非重复。
Bearer/token 从加密 secret store 按 key 取(secret_name),不走明文参数。
bas_point_list— 列控制器 point/object(跨厂商归一化:id/name/value/unit/status)bas_point_read— 单/多点 present-valuebas_alarm_list— 控制器活动告警/事件(归一化)bas_trend_read— 单点历史趋势样本(有界 ≤5000)bas_command— [WRITE][HIGH][MOC](默认 off:dry_run=True+ 审批双确认;捕获改前值供 undo)。 生命安全点(fire/smoke/egress/加压)一律拒绝——联网前即拒,绝不下发。- 厂商方言(metasys/niagara:资源路径 + 字段别名)仅存在于连接器内;oBIX 原生 XML / 精确写语义 待核实。
MQTT(可选叠加 sparkplug 组;IoT 传感器/网关)
mqtt_read_topic— 裸 MQTT 有界收集;uns_browse— 主题树浏览- 完整 Sparkplug B/UNS 工具清单见 iaiops-factory skill
mqtt_publish— [WRITE][HIGH][MOC](默认 off)
楼宇专属(edition 工具;仅随 building edition 加载,不进全局脑)
economizer_check— AHU 经济器故障检测(FDD):检出同时供冷供热(纯浪费)、该用自然冷却 却没用(室外够冷但新风阀在最小位且机械制冷开)、越高限还开阀(把热风引进来)。逐 AHU 判定, worst-first,每故障引用温度/状态。读数来自 BACnet AI/BI 点。zone_comfort— 区域舒适度 + 室内空气质量(ASHRAE 55/62.1):逐区判温度 20–26°C、相对湿度 30–60%、CO₂ ≤1000 ppm(通风充分性代理),越界即 breach,worst-first,引用数值。读数来自 BACnet AI 点。
跨协议脑(永远随 server 暴露)
- 诊断:
diagnose_dataflowdowntime_root_causedowntime_root_cause_livedowntime_triagelearn_cause_weightsrca_corpus_from_maintenancehistorian_healthalarm_bad_actorstag_healthsubscription_healthheartbeat_healthalarm_flood_analysisalarm_cascadealarm_rationalization_worksheet - 数据质量:
data_quality_scorecarddata_quality_fleet_rollup - 分析:
oee_computedowntime_eventsoee_multidimmonitor_changeshealth_summary(deprecated)anomaly_scan(deprecated) - 资产:
asset_inventorycross_protocol_asset_modeladopt_alias_mapdiff_alias_map - 基线:
baseline_learnbaseline_checkbaseline_record_changebaseline_status(change-log 基线:拒学薄历史、只报持续越带、每次告警必引基线样本 —— 非黑盒异常检测) - 合规/信创:
compliance_mappingcompliance_frameworkscompliance_dengbao_levelscompliance_reportcompliance_evidence_bundlehistorian_pushexport_datahistorian_queryhistorian_coveragestream_publishstream_publish_eventrca_narratefleet_statusfleet_incidentspdm_forecasthistorian_pushexport_data - 程序解读:
plc_program_outlineplc_program_xrefplc_program_sectionplc_program_visibility(解读导出的 ST/AWL/L5X 程序,只读文件,强制引用行号) - 医疗设施(healthcare facility 安全):
isolation_room_check— 隔离病房压差合规(ASHRAE 170 / CDC:空气传染隔离 AII 负压、保护性环境 PE 正压,≥2.5 Pa);检出反向/不足/低裕度,worst-first,每项引用读数。读数来自bacnet_read_points的压差 AI 点或历史库,纯分析。 - 元:
protocols_supported
Workflows
- Doctor-first:
protocols_supported→iaiops doctor→bacnet_discover(Who-Is 有响应才谈读点)。 - Read-first:
bacnet_object_list→bacnet_read_points快照 → 趋势用bacnet_read_trend_log,变化捕获用bacnet_cov_subscribe; "没数据"用diagnose_dataflow,坏点排名用tag_health。 - MOC 写:
bacnet_write_property(与可选mqtt_publish)为 [WRITE][HIGH][MOC]:默认dry_run=True、捕获改前值供 undo、iaiops approve具名审批双确认。写设定值可影响在运楼宇设备 —— 未经授权绝不写。
支持版本矩阵(内部 HLD §8,设计文档不随本仓发布;待核实 不得当既成事实)
| 协议 | 库(pin) | 规范/版本 | 覆盖 | 传输 | 自测 |
|---|---|---|---|---|---|
| BACnet/IP | BAC0>=2023.6,<2026(extra) |
ASHRAE 135 Annex J | 暖通/楼宇/厂务控制器 | UDP/47808 | ✅ 读路径 verified 2026-07-02(真 bacpypes3 虚拟设备);live HVAC 写/COV/trend 待核实 |
| Modbus-TCP | pymodbus>=3.5,<4 |
App 1.1b3;FC 1/2/3/4/5/6/15/16 | 电表/冷机/任意 TCP 从站 | TCP/502 | ✅ |
| Modbus-RTU | pymodbus>=3.5,<4 + pyserial>=3.5 |
Modbus serial (RTU) | 串口表计 | RS-485/serial | ✅ socat PTY verified 2026-07-02;物理 RS-485 待核实 |
| IO-Link | requests>=2.31,<3(复用 MTConnect pin) |
IO-Link Master JSON Integration(IOLINK-JSON);ifm IoT-Core / plain-REST 双 flavor | 带 JSON/REST 接口的主站(ifm/Balluff/Turck 类) | HTTP REST/JSON | ✅ mock 主站(双 flavor);live master 待核实 |
| MQTT | paho-mqtt>=2.0,<3 |
MQTT 3.1.1/5(裸 MQTT + SpB) | IoT 传感器/网关/Broker | TCP/1883/8883 | ✅ |
| BAS: Metasys OpenBlue REST | requests>=2.31,<3(复用 MTConnect pin,无新 HTTP 依赖) |
Metasys REST API v4(/objects·/alarms·/trendedAttributes);JC OpenBlue 监控控制器 |
NAE/SNE/SNC 类监控控制器聚合的 BACnet 现场点 | HTTPS + Bearer token | ✅ mock 控制器(in-repo);live 设备写/trend/告警 待核实 |
| BAS: Niagara 4 oBIX/REST | requests>=2.31,<3(复用 MTConnect pin,无新 HTTP 依赖) |
Niagara 4 oBIX/REST(/obix/config·/obix/alarms·/obix/histories);JSON 建模,原生 oBIX-XML 待核实 |
Tridium JACE / Niagara Supervisor 下的点/告警/历史 | HTTPS + Bearer token | ✅ mock 控制器(in-repo);live 设备 + oBIX-XML 编码 待核实 |